Podsumowanie treści

Strona 1 - SMART ELECTRONICS

SMART ELECTRONICSSMART ELECTRONICSHD Cabinets and CountersHD Cabinets and CountersTrainer: Lorenzo GiustiCustomer Support Refrigeration Platform

Strona 2 - User interface analisys

10Category Type food Temperature Umidity5 Drinks 8°C-2°C75%0°C90%90%75%4°C6°C 90%1White & game meat2 Pork & Beef meat3 Cheese,salted meat4 Veg

Strona 3

11Set the Food CategorySet the Food Category((FREEZERFREEZER))ADVANTAGE FOR THE CHEF MANAGER:Humidity & temperature are locked at the optimal cond

Strona 4 - Where can You find IT?

12How to set the category WHAT TO DO:Keep pressed and select category up or downDisplay shows, for each category, the stora

Strona 5

13The new food category will be memorized automaticaly if button is not pressed for 5 seconds.In the display will be visualized in the left side the

Strona 6 - DESCRIPTION OF MAIN BOARD

14SMART DEFROSTWith the new electronic control the defrosting cycles are made only when it is necessary (it is an Electrolux patent); this means that

Strona 7 - Description of the connectors

15OBJ: 24 hrs. per day temperature monitoring andrecord keeping of the temperature over the critical limitALARM CONDITIONS:-the display shows an alar

Strona 8 - I.E. Electric diagram

16HOW TO CHECK IT?In the display rolling the label i.e. TEMP +14°C1. Press the button and the buzzer switch OFF2. Press the button an

Strona 9 - MANUAL Setting Temperature

17HOW TO CHECK IT?When the alarm has occurred the display shows the label TEMP Critical temperature14°C10°C5°Cset point temp.time16.00 17.00 18.00 1

Strona 10 - REFRIGERATOR)

18ProbesThe unit with the new electronic control is supplied with 4 probes:“S” - Storage probe: measuring inner temperature“E” - Evaporator probe: mea

Strona 11 - 2 Ice cake

19How to check temperature Probes1. Pressing the following buttons together you may see the value of the temperature of the first probe1. Pressing t

Strona 12 - How to set the category

21. Temperature setting 2. Manual defrostHigh Humidity -led ON (90%)Low Humidity -led OFF (75%)Food category: automatic set of the optimal temperature

Strona 13

20Where you can find Them?i.e. CabinetInside the cellInside the cell(right side)(right side)Inside of EvaporatorInside of Evaporator(to defrost)(to de

Strona 14 - SMART DEFROST

21Where you can find Them?In front of condenserIn front of condenser(by ventilation)(by ventilation)Room probeIn the right side of CondenserIn the rig

Strona 15 - HACCP History

22Which type of probes are used in the smart electronic?Condenser/room probe temperatureCondenser/room probe temperature1.1.NTC Semitec 10 K 25°CNTC S

Strona 16

23Which type of probes are used in the smart electronic?Evaporator probe temperatureEvaporator probe temperature1.1.NTC 10 K SMDNTC 10 K SMD2.2.Range

Strona 17

24The following parameters are kept and recorded, for 7 days:& Performance (CAP)”Coefficent appliance’s Performance”& Min and Max “Cell” tempe

Strona 18

25What’s means (CAP)?CAP (COEFFICENT APPLIANCE’S PERFORMANCE)The CAP is a qualitative evaluationregarding the utilisation of the appliance. It is base

Strona 19

26How can you check theseven days historyTo check out the the history parameters,1. Press the buttons together for 3 second and the display will show

Strona 20 - Where you can find Them?

27Programming ParametersThe Electronic board allows the adjustment of 94 parameters, through two Programming routines.1. We have 17 USER PARAMETERS,

Strona 21

28Programming ParametersUser parameters1) To have access to the USER PARAMETERS press the buttons increase & decrease for 4 seconds.Now the displ

Strona 22

295 PROGRAMMING PARAMETERS Name Setting the real time MIN Set the time: minute. HOUR Set the time: hour. DAY Set the date: day. MON Set the date

Strona 23

31. Temperature setting 2. Manual defrostFood category: automatic set of the optimal temperature & humidity for each kind of food1. To check alarm

Strona 24

30Name Alarms CDIF Alarm temperature type for cell “A”= absolute “r”= relative (compared to set point) HAL High temperature alarm for cell. LAL Low t

Strona 25 - What’s means (CAP)?

315 PROGRAMMING PARAMETERSName Display and Printer FHUM Humidity setting. “Enable and disable the humidity button” DIR Display resolution. “Full

Strona 26 - How can you check the

325 PROGRAMMING PARAMETERSName Printer TPRN Printing interval time PRND Enable short daily report. “Y”= print only alarms “N”= print temperature cel

Strona 27 - Programming Parameters

331) To have access into the FACTORY PARAMETERS press the buttons increase & decrease for 4 seconds.Now the display visualizes the time and the da

Strona 28 - User parameters

34 Name SET POINT Setting DIFP Positive differential (re-start compressor). Set +DIFP DIF- Negative differential (stop compressor). Set - DIF HSP H

Strona 29

35Name Alarm setting ADI Alarm differential “High /low temperature” ADY Alarm delay. “High /low temperature” AOR Alarm time after power on. DOT Doo

Strona 30

365 PROGRAMMING PARAMETERSName Defrost HTC High temperature of condenser. “alarm” DCS Defrosting counting system. ABS= absolute time HCP= working ho

Strona 31

375 PROGRAMMING PARAMETERSName Defrost DOD Defrost delay at power on. DIN Defrost interval between two defrosting cycles.DTO Defrost timeout. DST Defr

Strona 32

385 PROGRAMMING PARAMETERSName Defrost DRT Drainage time. TDF Evaporator fan temperature delay to start. CETO Timeout for evaporator fan after defro

Strona 33 - Factory parameters

395 PROGRAMMING PARAMETERSName Other parameters UNI Measure Unit “C= Celsius degrees” “F= Fahrenheit degrees” P4T Enable printing temperature of all

Strona 34

4Where can You find IT?Where can You find IT?In the HEAVY DUTY Cabinet one door and two doors.Lift up the control panel and remove the back protection

Strona 35

405 PROGRAMMING PARAMETERSName Other parameter TROO Room sensor type. Nus= not used; NTC2= 10K sensor; NTC3= 10K sensor (SEMITEC) TCND Condenser sen

Strona 36

41O To have acces into the SERVICE ALARM press the button for 4 seconds.O Now the display visualizes the first SERVICE ALARM memorized in the electro

Strona 37

426 ALARMLABEL TYPE ACTION DOOR OPEN Check the door HACCP alarm full Reset history memory High temp. condenser Check the condenser if is dirty o

Strona 38

43Service alarm Type “E” S_SC (storage sensor) “Sensor short-circuited.” S_OP (storage sensor) “Sensor is broken or disconnected.” E_SC (evaporato

Strona 40

5Where can You find IT?Where can You find IT?In the HEAVY DUTY Counter freezer and refrigeratedExtract the control panel from table and remove the up

Strona 41 - Service alarm

6DESCRIPTION OF MAIN BOARDDESCRIPTION OF MAIN BOARDJ3J8J2J1(1 – 2)...J4J7J1(3 – 4)

Strona 42 - Service alarm Type “b”

7Description of the connectorsDescription of the connectorsPosition DescriptionJ1 POS. 1-2CONDENSER PROBE CONNECTOR type LUMBERG 2.5 MSF 4J1 POS. 3-4A

Strona 44

9MANUAL Setting Temperature MANUAL Setting Temperature 1. Press the button ON/OFF for 3 seconds.Now all of the led in the electronic board are blinkin

Komentarze do niniejszej Instrukcji