18
Adjustment of minimum level of plate burners.
When changing the gas type, watch that the minimum
level be correct. A regular flame at minimum level is
about 4 mm; check that, turning quickly the knob from
the maximum to the minimum position, the burner
doesn’t go out.
Adjustment of minimum level for the hob burners
The burner is correctly adjusted when the flame is
stable silent and goes out without any noise.
When changing the type of gas check that the
minimum level is correct. The air admission is correct
when the flame is about 4 mm in length.
The top burners do not need adjustment of primary
air.
Check that, turning the knob quickly from the
maximum position to the minimum one, the flame
does not go out.
no air
correct
adjustment
excess of
air
Flame adjustment
To adjust the minimum level:
• Light the burner
• Turn the knob to minimum level;
• Remove the knob;
• Unscrew or screw the by-pass screw (see
figure) until a regular small flame is reached.
For LPG screw completely the by-pass screw.
Reassemble the parts following the same procedure
in reverse.
Check that, when turning the knob quickly from the
maximum position to the minimum one, the flame
does not go out.