Electrical Connection
Any electrical work required to install
this appliance should be carried out
by a qualified electrician or
competent person, in accordance
with the current regulations.
THIS APPLIANCE MUST BE
EARTHED.
The manufacturer declines any liability should
these safety measures not be observed.
This appliance is designed to be connected to
a 230 V 50 Hz AC electrical supply.
Before the appliance is connected:
1) check that the main fuse and the domestic
installation can support the load (see the
rating label);
2) check that the power supply is properly
earthed in compliance with the current rules;
3) check the socket or the double pole switch
used for the electrical connection can be
easily reached with the appliance built in the
forniture unit. Before switching on, make sure
the electricity supply voltage is the same as
that indicated on the appliance rating plate.
The rating plate is located on the bottom of
the hob. A copy is attached on the back cover
of this book.
The appliance is supplied with a 3 core flexible
supply cord incorporating a plug. Connect the plug
to an adequate socket.
Permanent Connection
In the case of a permanent connection, it is
necessary that you install a double pole switch
between the appliance and the electricity supply
(mains), with a minimum gap of 3 mm between the
switch contacts and of a type suitable for the
required load in compliance with the current electric
regulations.
The switch must not break the yellow and green
earth cable at any point and it should be 2-3 cm
longer than the other cables.
Ensure that the hob supply cord does not
come into contact with surfaces with
temperatures higher than 50 deg. C.
Replacement of the connection cable
The connection of the voltage cable to the
appliance's terminal block is of type "Y". This
means that its replacement requires the
specific equipment of a technician. In this case,
only cable type H05V2V2-F T90 must be used.
The cable section must be suitable to the vol-
tage and the working temperature. The yellow/
green earth wire must be approximately 2 cm.
longer than the phase wires (Fig. 7-a).
To open the terminal block and reach the
terminals, proceed as follows:
" insert the point of a screwdriver into the
visible protrunding part of the terminal block;
" exert a light pressure and lift (Fig. 7-b)
Earth
(yellow/green)
Neutral
Fig. 7
a
b
Przeglądanie stron 17