Zanussi ZCG62496XA Instrukcja Użytkownika Strona 24

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 23
If the appliance is set for liquid gas
you can change it to natural gas, with
the correct injectors.
The gas rate is adjusted to suit.
WARNING! Before you replace the
injectors, make sure that the gas
knobs are in the Off position.
Disconnect the appliance from the
electrical supply. Let the appliance
cool down. There is a risk of injury.
The appliance is set to default gas. To
change the setting choose a pipe
holder from the list. Always use the
gasket sealing.
A CB
A. Gas connection end
B. Natural Gas pipe holder
C. LPG pipe holder
HOB INJECTORS REPLACEMENT
Replace the injectors when you change the gas
type.
1. Remove the pan supports.
2. Remove the caps and crowns of the burner.
3. Remove the injectors with a socket spanner 7.
4. Replace injectors with the ones necessary for
the type of gas you use.
5. Replace the rating plate (it is near the gas
supply pipe) with the one for the new type of
gas supply.
You can find this plate in the bag
supplied with the appliance.
If the supply gas pressure is not constant or it is
different from the necessary pressure, install an
applicable pressure adjuster on the gas supply
pipe.
ADJUSTING THE MINIMUM GAS LEVEL ON
THE HOB BURNER
1. Disconnect the appliance from the electricity.
2. Remove the knob for the hob. If there is no
access to the bypass screw dismount the
control panel before adjustment start.
3. With a thin and flat screwdriver adjust the
bypass screw A.
The model determines the position of the
bypass screw A.
A
A
Changing from natural gas to liquid gas
1. Fully tighten the bypass screw.
2. Put the knob back.
Changing from liquid gas to natural gas
1. Unscrew approximately one turn the bypass
screw position A.
2. Put the knob for the hob back.
3. Connect the appliance to the electricity.
24
Przeglądanie stron 23
1 2 ... 19 20 21 22 23 24 25 26 27 28

Komentarze do niniejszej Instrukcji

Brak uwag