G20 (2H) 13 mbar =
2500 W (only for Rus-
sia)
Electric supply: 230 V ~ 50 Hz
Category: ll2H3B/P (for Russia
and Romania)
II2H3+ (for Portugal)
Gas Supply: G20 (2H) 20 mbar
Appliance class 3
Gas Oven Burner Data
Gas type
Injector
mark
Nominal
gas pow-
er
Nominal
gas flow
Reduced gas
power
By-pass nee-
dle
Nominal gas
pressure
1/100 mm kW
g/h (1/100 mm)
(mbar)
Natural gas
(G20)
114 2,7
-
1,0 Reg. 20
Liquid gas
(G30/G31)
78 2,5
182
1,0 52
30 / 30
(Only for Por-
tugal)
Natural gas
(G20) (Only
for Russia)
124 2,5
-
1,0 Reg. 13
Installation
Warning! Refer to the Safety chapters.
Safety for installation
These installation instructions are for authorized
persons only!
Warning! Let only authorized persons
(gas and electricity) do the installation,
connection and maintenance of the appliance.
If you do not refer to an authorized person, the
guarantee becomes invalid if there is damage.
Follow the correct procedure and the
instructions in this user manual for installation,
operation and maintenance of gas and
electrical appliances.
Warning! Before installation, make sure
that the local supply conditions (the type
of gas and the gas pressure) and the
adjustment of the appliance are compatible.
Warning! The adjustment conditions for
this appliance are located on the label or
rating plate.
Warning! The manufacturer is not
responsible for damages caused by an
installation which does not agree with the
instructions in the manual.
Installation environment:
• This appliance is not connected to a com-
bustion products evacuation device.
• Only install the appliance in a room with suf-
ficient ventilation.
• Keep natural ventilation holes open or install
a cooker hood.
• There must be a 130 cm² minimum opening
in the built-in cabinet.
The use of a gas cooking appliance results in
the production of heat and moisture in the room
in which it is installed. Ensure that the kitchen is
well ventilated: keep natural ventilation holes
open or install a mechanical ventilation device
(mechanical extractor hood). Prolonged inten-
sive use of the appliance may call for additional
ventilation, for example opening a window, or
13